REMOVING AND REPLACING ACTUATOR

General information

All repair work is best performed when the actuator is

removed from the valve body.

However, many service repairs and adjustments can be

accomplished in the field while the actuator and valve
body are still connected to each other.

WARNING:

Ensure that the plug assembly is not rotated

with the plug seated. This may cause irreparable damage
to the seating faces.

Always remove the yoke (7) with the actuator as an

assembly.

6.1

Remove actuator

6.1.1 On actuators with air-to-close action partially vent

actuator, on actuators with air-to-open action apply
supply pressure to raise the plug (half stroke).

CAUTION:

Galling of critical surfaces may result if the

plug is not correctly positioned between seat ring and
bonnet.

6.1.2 With a wrench, hold the actuator stem to prevent it from

rotating while using a second wrench to loosen the plug
stem locknut on the plug stem (27) or coupling screws
(28).

6.1.3 Loosen the packing nut as far as possible.

6.1.4 Loosen the slotted nut as far as possible.

6.1.5 Completely rotate the actuator off the plug stem by

continuously loosening locknut, packing nut and slotted
nut ensuring that the plug stem does not rotate in the
bonnet.

CAUTION:

Do not allow the plug to drop and impact

against the seat after turning the actuator off the plug
stem threads.

6.1.6 When the actuator is free release supply pressure and

remove actuator.

6.2

Replace actuator

The actuator stem must be fully extended:

Actuators with air-to-open action must be fully vented.
Actuators with air-to-close action apply supply pressure.

6.2.1 As required remove packing nut and slotted nut from

the valve bonnet.

6.2.2 Manually depress the plug stem to ensure the plug is

fully seated.

6.2.3 Place the actuator over the valve adding slotted nut,

and packing nut.

6.2.4 Thread the plug stem locknut as far as possible onto

the plug stem.

6.2.5 Engage the plug stem and coupling threads and rotate

actuator in a clockwise direction until the clearance
between the yoke base and the bonnet seating face is
around 2 mm.

WARNING: Ensure that the plug assembly is not rotated

with the plug seated. This may cause irreparable
damage to the seating faces.

6.2.6 On actuators with air-to-close action partially vent

actuator, on actuators with air-to-open action apply
supply pressure to raise the plug (half stroke).

6.2.7 Tighten slotted nut.

6.2.8 With a wrench, hold the actuator stem to prevent it

from rotating while using a second wrench to tighten
the plug stem locknut against the coupling.

6.2.9 Tighten packing nut (see table 1).

6.2.10 Vent actuator and adjust travel indicator (9).

STOP!

STOP!