Explanatory Notes

(continued)

K

vs

Values and Actuator Selection Data

Important

In the installation instructions, standard values are described. For possible
deviations, please see the name plate of the control valve.

DN

Characteristic

∆p max.

[bar]

K

vs

[m³/h]

25 – 80

linear/equal %.

300

1

1.5

2.3

3.6

5.5

8

11

13

25 – 80

linear/equal %.

370

4.5

7

9.5

10.5

80 – 150 linear/equal %.

300

2.3

3.6

5.5

11

14.5

17

80 – 150 linear/equal %.

370

4.5

9

12

DN

Valve stroke

[mm]

Revs./Stroke

Max. admissible torque

for opening. [Nm]

Type/size of
actuator
DIN ISO 5210

7

120

F10 – B1

25 – 80

35

5.8

310

F14 – B1

7

120

F10 – B1

80 – 150

35

5.8

310

F14 – B1

Advertising