3.1

Application

Control Valve

3.2

Pressure rating

PN 10

3.3

Temperature range

0 °C to 100 °C

3.4

Valve function

To ensure optimum valve function, observe the flow
direction from connection a to connection b.

3.4.1 Function: air-to-open – spring-to-close

Product flow direction ab (see fig. 1)
Product flow direction closed by spring force.

3.4.2 Function: spring-to-open – air-to-close

Product flow direction ab (see fig. 1)
Product flow direction closed by air force.

3.5

Material data

Seals in contact with the medium

Valve plug

1.4435

Aseptic diapragm

TFM / EPDM

Operating temperature

max. 100° C

Sterilisation temperature

130° C

Operating pressure

max. 1.6 Mpa

Seals not in contact with the medium

O-Rings

Silicon

Stainless steels

In contact with the medium

1.4404

Not in contact with the medium 1.4301

3.6

CIP cleaning agents

Nitric acid 3% / Temperature 80° C

Soda lye 3% / Temperature 80° C

3.7

SIP sterilisation agents

Hot water / Temperature 130° C

Steam / Temperature 130° C

3.8

Surfaces

In contact with medium

Ra ≤ 0,6 µm

Ra ≤ 0,5 µm Elec.-polished (opt.)

Ra ≤ 0,4 µm Elec.-polished (opt.)

Not in contact with medium Metal, turned bright

3.9

Valve connection piping

Installation position

Vertical, to ensure valve and line drain free.

3.10

Connection types

DIN 11850 series 2 (DN10 - 100) weld ends
ISO 2037 / BS 4825 weld ends
DIN EN ISO 1127 weld ends
DIN 11864 Form A threaded connection
DIN 11864 Form A flange connection
DIN 32676 clamp connection
ISO 2852 clamp connection

3.11

Pipe connection

Separable (for disassembly).

3.12

Welding instruction

See

welding instructions (sec. 5.4).

3.13

Installation

See

assembly and disassembly instructions (sec. 6).

3.14

Electrical and pneumatic connections
Assemble after fitting the valve.

3.14.1 Electrical connections

WARNING:

Electrical connections to be made by a

qualified electrician only.
• Observe valid VDE-EVU and other local regulations.
• Check operating voltage and amperage of specific
parts before connection.

3.15

Quality of supply air

Pressure

6 bar (87 psi)

Solid particles

Particle size max. 5 mm (0.4 in.)
Particle density max. 5 mg/m

3

(quality class 3)

Water content

Dew point +2° C (35.6 °F)
(quality class 3)

Oil content

Oil free, max. oil content
25 mg/m

3

(quality class 3)

STOP!