11. Place the Gasket (pc# 22) in position on the Base (pc# 2).

12. Separately, install the upper O-ring (pc# 15) and lower Oil Seal (pc# 25) in the Housing (pc# 1).

NOTE: Lubricate all O-rings before installation.

13. Lower the Housing (pc# 1) into position onto the Base (pc# 2) using the Eye Bolts (pc# 23) and secure with the Cap Screws (pc# 9).

a

CAUTION: Care must be taken to ensure that the O-ring (pc# 15) and Oil Seal (pc# 25) located in the Housing (pc# 1) are not damaged

during reassembly.

14. Separately, install the upper Oil Seal (pc# 25) in the Input Flange (pc# 8).

15. Install the Input Flange (pc# 8) with upper Oil Seal (pc# 25) over the Input Shaft & Pinion (pc# 4) onto the Housing (pc# 1) and secure using

the Cap Screws (pc# 10).

a

CAUTION: Care must be taken to ensure that the Oil Seal (pc# 25) located in the Input Flange (pc# 8) is not damaged during reassembly.

NOTE: Lubricate sealing surfaces of the Input Shaft (pc# 8) and Oil Seal (pc# 25) before reassembly.

16. Install the Key (pc# 24) onto the Input Shaft & Pinion (pc# 4).

17. Lower the Stem Nut (pc# 5) through the top of the Housing (pc# 1) and into position in the Drive Sleeve (pc# 6) using the Eye Bolts (pc# 23)

provided.

a

CAUTION: Ensure splines are properly engaged and Stem Nut (pc# 5) fully seated in position in the Drive Sleeve (pc# 6).

18. Install the two threaded Lock Nuts (pc# 7) into the Drive Sleeve (pc# 6), accessing through the top of the Housing (pc# 1).

19. Separately, install the O-rings (pc# 26 and pc# 27) onto the Stem Cover Adapter (pc# 28).

NOTE: Lubricate all O-rings before installation.

20. Install the Stem Cover Adapter (pc# 28) with O-rings (pc# 26 and pc# 27) into the Housing (pc# 1). Tighten the Set Screw (pc# 20).

NOTE: Upon reassembly, ensure the Input Shaft can be rotated freely without binding.