[File]

DescText = “DeviceNet Network”;

CreateDate = 12-6-1999;

CreateTime = 9:04:46;

ModDate = 12-6-1999;

ModTime = 9:04:46;

Revision = 2.0;

[Device]

VendCode = 469;

ProdType = 7;

ProdCode = 2112;

MajRev = 4;

MinRev = 118;

VendName = “Worcester Controls Corporation”;

ProdTypeStr = “General Purpose Discrete I/O”;

ProdName = “ACCESS/DeviceNet”;

Catalog = “07159”;

[IO_Info]

Default = 0x0001;

PollInfo = 0x0001,1,1;

Input1 = 11,0,0x0001,
“Producing IO/Data”,6,“20 04 24 65 30 03”,“Help”;

Output1 = 1,0,0x0001,
“Consuming IO/Data”,6,“20 04 24 66 30 03”,“Help”;

[Params]

Param1 =

0,

$ parameter value slot

6, “20 08 24 01 30 03”,

$ link size and path

0x32, $

descriptor

4, 1,

$ data type, 1 byte(s)

“Input State Instance 1”,

$ parameter name

“”,

$ units string

“Discrete Input Point\n\n”,

0,1,0,

1,1,1,0,0,0,0,0,0;

Param2 =

0,

$ parameter value slot

6, “20 08 24 02 30 03”,

$ link size and path

0x32, $

descriptor

4, 1,

$ data type, 1 byte(s)

“Input State Instance 2”,

$ parameter name

“”,

$ units string

“Discrete Input Point\n\n”,

0,1,0,

1,1,1,0,0,0,0,0,0;

FCD WCAIM2022-01

(Part 14120)

Worcester Controls Supplement 3
ACCESS I and M DeviceNet EDS File

Installation, Operation and Maintenance Instructions

$ Advanced DeviceNet Monitor Electronic Data Sheet

$ Complies with EDS File Syntax Checking Utility – 02.02