Page 2 of 2

Performance

Maintenance

The FC1, FCDA and FCSR modules have a maximum of
only two moving parts. As such, the modules are virtually
maintenance free. Should any problems arise with the FC1,
FCDA or FCSR, consult factory.

How to Order

Order part number FC1 for single direction flow control.
Order part number FCDA for dual direction flow control for
DA actuators. Order part number FCSR for dual direction
flow control for SR actuators order appropriate NAMUR
mount bolt kit from chart at right.
Example: To order FCDA to be sandwich NAMUR

mounted with A25N solenoid valve, order
FCDA and NBK45.

Bill of Material

Item

Material

Body

Aluminum, Anodized

Adjustment Screws

Brass

Check Ball

Nitrile

Retaining Ring

Spring Steel

NAMUR Accessory Bolt Chart

Other NAMUR accessories:
l. LV1:

Sandwich mount lockout and vent valve
for use with gear overrides and/or OSHA
lockout/tagout procedures.

2. APS1: Air purge system for spring retum

actuators sandwich mount with A25N
solenoid valve.

3. APS2: Air purge system for spring return

actuators Namur mount for remote/line
mount solenoid valves.

4. NPT1: 1/4" NPT adapter plate.
5. A25N: NAMUR mount solenoid valve.
6. NPTELB:1/4" NPT 90

°

adapter plate.

Note: See appropriate lOM’s for additional information on
above NAMUR accessories.

How to Specify

The single direction flow control shall be an Automax FC1
module. The dual direction flow control for double acting
actuators shall be an Automax FCDA module. The dual
direction flow control for spring return actuators shall be
an Automax FCSR module. The flow control module shall
be capable of being sandwich NAMUR mounted with other
NAMUR mount accessories.

FC1/FCDA

FCSR

FC#

LV1

APS1

APS2

NPT1

A25N

Bolt Kit

Bolt Kit

NBK25

NBK40

NBK50

NBK65

NBK50

NBK60

NBK45

NBK55

NBK70

NBK80

NBK55

NBK65

NBK80

NBK90

NBK75

NBK85

Temperature: -20

°

F to 180

°

F.

Pressure:

20 psig to 100 psig.

Media:

Dry or lubricated non-corrosive gas
compatible with nitrile seals.

Estimated Cv: 0.68 inlet.
Performance: See graphs on above.