Typical actuator specifications – Flowserve CE Series Automax CENTURA User Manual

Page 10

Advertising
background image

Automax CENTURA™ CE Series FCD AXENIM0037-01 – 12/05

10

Typical Actuator Specifications

Action

Reversible

Range of Adjustability

0° -270°

Supply Voltages

AC:

115 VAC

+/-10%

230 VAC

50/60 Hz

24 VAC

DC:

12 VDC
24 VDC

Temperature Rating

-40°F (-40°C) to 160°F (70°C)

Enclosure Ratings

Nema 4, 4X, 7, 9 Watertight and Explosion-proof
Class I Groups C&D, Div. 1&2
Class II Groups E, F&G, Div. 1&2

Motor Types

AC:

Permanent Split Capacitor, Class B Insulation

DC:

Brush

AC Motor Thermal Protection

Automatically resetting

Travel and Aux. Switches

SPDT, Form C
15 amp 125 VAC 1/2 HP, 10 amp 250 VAC, 1/2 amp 125 VDC

Conduit Connections

3/4-14 NPT

Manual Override

300 In-lbs max input

Corrosion Protection

Chromate conversion undercoat with polyester electrostatic powder top coat

Terminal Strip Hookup

300V, 30 amp, 12-26 AWG

Lubrication

Permanently lubricated

Gear Train

Heat treated alloy steel able to withstand stall torque

Note: The above ratings may change depending on model configurations and options provided. Products may

differ as the result of the Company policy of continuous product improvement.

Motor

option

Motor

Voltage

Duty

Cycle

(1,3)

Run

Current

(amps)

Locked

Rotor

(amps)

Cycle times in Seconds per 90 Degrees

actuator Model

CE2

CE4

CE7

CE1

CE5

Std.

115 AC

25

1.1

1.3

3

5

6

11

18

A

115 AC

Extended: 75

0.5

0.6

6

10

17

24

36

B

12 DC

100

1.6

3.0

(2)

6

9

16

21

32

C

24 DC

100

0.9

2.0

(2)

6

8

15

20

30

D

230 AC

25

0.7

0.8

3

5

6

11

18

F

230 AC

Extended: 75

0.3

0.4

6

10

17

24

36

J

24 AC

100

0.5

0.8

3

5

6

11

18

torque and Weights

Torque (In-Lbs)

250

400

700

1000

1500

Torque (N-M)

28

45

79

113

169

Weight (Lbs)

18

18

18

18

20

Weight (Kg)

8

8

8

8

9

Notes:
1. Duty cycle is the limit of “on” time as percentage of total cycle time. For example, the CE2 with standard motor

runs 3 seconds to open or close the valve. The motor must remain off for 9 seconds prior to starting the close

cycle. DC motors may be operated continuously.

2. Do not lock up DC motors.
3. CE5 duty cycles for AC motors are 20% for standard duty and 70% for extended duty.
. For 180 degree applications, simply multiply the above cycle times by 2.

Advertising