Page 3 of 4

Buna - R (Actuator Base Model No.) SKB
Viton - R (Actuator Base Model No.) SKV

ie., Buna Seal kit for R312SR80 is R312SKB

Standard Nitrile

-20

°

F to 175

°

F

High Temp.

Viton

0

°

F to 300

°

F

Reassembly Procedures

1. Inspect all parts for wear and replace any worn parts as

needed. Normally, all Seals and Gaskets should be
replaced when reassembling an actuator.

2. Clean and grease all components with a multi-purpose

"polymer" fortified grease such as DuBois Chemical
MPG-2. For low temperature units use Dow Corning

®

55 low temperature grease.

3. Reverse the disassembly procedures to reassemble.

Use the proper torque from the torque chart on the Tie
Rod Locknuts (28) , the Adaptor bolts (43), the Spring

Bolt Torques

Piston Bolt (25) (SAE Grade 8 Bolt)
Actuator Size

Bolt Size

Torque Range

AR205-AR208

3/4"-10 UNC

271-300 FT-LB

AR310-AR416

1-1/4"-7 UNC

537-591 FT-LB

AR418-AR422

1-1/4"-7 UNC

832-916 FT-LB

Tie Rod (27) (A311 Stressproof Rod)
Actuator Size

Bolt Size

Torque Range

AR205-AR208

5/8"-11 UNC

117-130 FT-LB

AR310-AR312

3/4"-12 UNC

207-229 FT-LB

AR314-AR416

7/8"-9 UNC

336-371 FT-LB

AR418-AR422

1"-7 UNC

503-556 FT-LB

Adaptor Bolt (43) (SAE Grade 5 Bolt)
Actuator Size

Bolt Size

Torque Range

AR205-AR208

5/8"-11 UNC

123-136 FT-LB

AR310-AR422

3/4"-10 UNC

217-240 FT-LB

Spring Cartridge Stud (ASTM A193 Grade B7)
Actuator Size

Bolt Size

Torque Range*

AR205-AR208

1/2"-13 UNC

64-71 FT-LB

AR310-AR316

3/4"-10 UNC

226-249 FT-LB

AR414-AR422

1"-7 UNC

546-603 FT-LB

Cartridge Nuts (41) , and the Piston Bolt (25). These
threads should be lubricated with Locktite Threadlocker
242 or equivalent prior to assembly.

4. See attached drawing which depicts all required spare

parts.

5. Test the actuator for smooth operation and air leakage

at service pressure before re-installing.

Seal Kits

Temperature Ratings

*Note: It may be necessary to use a crowfoot
extension to reach the nuts on the spring cart-
ridge stud. In this case, the torque wrench
reading will differ from the actual torque
applied to the nut. Consult factory for proper
torque adjustment.