Heavy duty hydraulic override, Tie rod (7) (a311 stressproof rod) – Flowserve Heavy Duty Hydraulic Overrides User Manual

Page 3

Advertising
background image

Checking Oil Level
1.

Actuator should be in full CW position for DA ac-
tuator or failed position for SR actuator.

2.

Remove cap from oil reservoir and check oil
level.

3.

Oil level should be 2-3 inches from top of reser-
voir. If required, add hydraulic fluid to reservoir to
reach this level.

Pump/Oil Specifications
Temperature: 0°F to 300°F
Oil Type: Fire resistant, Nuclear Approved hydraulic

fluid, such as Exxon Firexx HS68. Consult
factory for seal compatibility and temperature
ranges of other fluids.

Oil Volume:

Actuator

SR/DA

Volume (gal)

RN2

SR

1/2

DA

1/2

RN3

SR

1/2

DA

3/4

RN4

SR

1

DA

1 1/2

Pump Pressure: DA

1500 psi

SR

3500 psi

Number of strokes to override:

Actuator

SR/DA

# Pumps

RN2

SR

17

DA

9

RN3

SR

45

DA

25

RN4

SR

132

DA

74

B00151-0

Page 3 of 4

11444 Deerfield Road
Cincinnati, Ohio 45242
(513) 489-7800
FAX (513) 489-5243

Heavy Duty Hydraulic Override

Nuclear Qualified Actuator

Bolt Torques

Piston Bolt (3) (SAE Grade 8 Bolt)*

Actuator Size

Bolt Size

Torque Range

RN2

3/4"-10 UNC

271-320 ft.lb.

RN3

1 1/4"-7 UNC

537-591 ft.lb.

RN4

1 1/4"-7 UNC

1014-1116 ft.lb.

* Not present in SR overrides

Tie Rod (7) (A311 Stressproof Rod)

Actuator Size

Bolt Size

Torque Range

RN2

5/8"-11 UNC

117-130 ft.lb.

RN3

3/4"-10 UNC

207-229 ft.lb.

RN4

1"-8 UNC

249-270 ft.lb.

Adapter Nut (12) and Stud (ASTM A193 Gr. B7)*

Actuator Size

Bolt Size

Torque Range

RN2

1/2"-13 UNC

64-71 ft.lb.

RN3

3/4"-10 UNC

226-249 ft.lb.

RN4

1"-8 UNC

546-603 ft.lb.

*Not present in SR Overrides