Technical data – Flowserve NRG 16-19 User Manual

Page 6

Advertising
background image

6

NRG 16-19, NRG 16-27, NRG 16-28

Service pressure

PN 40, max. 32 barg at 238°C
Connection

NRG 6-9, NRG 6-27: screwed

3

/

8

" to ISO 228-

NRG 6-28: screwed M 24 x .5
Materials

NRG 6-9

Screw-in type enclosure

Spacer disk

Electrode rod

Insulating disk

NRG 6-27, NRG 6-28

Screw-in type enclosure

Electrode rod

Insulation of electrode rod
Sensitivity of response

>  μS/cm at 25°C
Electrode voltage

2 V
Wiring

NRG 6-9: Connecting line made from PTFE, 2 m long, 2 x .5 mm

2

NRG 6-27, NRG 6-28: M 2 sensor connector, 5 poles, A coded
Protection

IP 65 to DIN EN 60529
Ambient temperature at terminal box

Max. 80°C
Weight

Approx. 0.3 kg

Technical Data

Gylon

®

is a registered trademark of Garlock GmbH, Neuss

Corrosion resistance

When used for its intended purpose the safe functioning of the electrode will not be impaired by

corrosion.

Advertising