Technical data, Orifices (o) – Flowserve UNA 23 User Manual

Page 6

Advertising
background image

6

Technical Data

The trap body must not be subjected to sharp increases in pressure.
The dimensional allowances for corrosion reflect the latest state of technology.

Sizing

UNA 23h/v, UNA 25h/v, UNA 26h/v, UNA 27h

1

) Observe pressure/temp. specifications.

2

) Inlet pressure minus outlet pressure.

Orifices (O)

O 2

2

O 4

4

O 8

8

O 13

13

O 16

16

O 22

22

O 28

28

O 32

32

O 45

45

Max. admissible dif-

ferential pressure

1

)

2

)

∆∆∆∆∆PMX [bar]

(Seat design)

UNA 23h/v

UNA 25h/v
UNA 26h/v

UNA 26h stainless steel

UNA 27h

Corrosion Resistance

When used for its intended purpose the safe functioning of the steam trap will not be impaired by
corrosion.

Pressure / Temperature Ratings

UNA 2... without sightglass cover:
For pressure / temperature ratings see indications on trap body or name plate: pressure class
PN / Class, material number, max. temperature, max. pressure, max. differential pressure.

UNA 23h/v: max. admissible temperature: 300 °C

UNA 25h/v: max. admissible temperature: 350 °C

UNA 26h stainless steel: max. admissible temperature: 300 °C

UNA 26h/v: max. admissible temperature: 400 °C

UNA 23h/v with sightglass cover: max. admissible temperature: 240 °C
Reduced temperature limits for sightglass cover with integrated reflexion water level indicator.
If the pH value is above 9.0 and the fluid temperature exceeds 200 °C the glass will get more wear.

Advertising