Commissioning, Annex, Trs 5-6 b, trs 5-6 c/d – Flowserve TRS 5-6 User Manual

Page 13

Advertising
background image

13

TRS 5-6 b, TRS 5-6 c/d

1. When switching on the mains voltage the green LED should be permantently

illuminated. Fig. 3

2. Raise temperature in heat generator until the permissible temperature limit is

exceeded. The two red LEDs on the temperature switch must light up.

3. After lowering the temperature the two red LEDs must extinguish.

4. An alarm ‘limit temperature exceeded’ can be simulated by pushing the button

TEST

I . On pushing the button the two red LEDs must light up.

5. To check the function of the self-checking circuitry of the temperature switch

proceed as follows: Set switch

TEST

II /

INSPECTION

in the direction of the arrow.

After max. two minutes the two red LEDs should signal alarm. The button

TEST

I must not be operated during this test nor must the adjusted limit

temperature be exceeded. After the test return switch into its original position.
After the response delay the two red LEDs must extinguish.

Check functions

Commissioning

– continued –

Fault:

The temperature switch signals alarm during normal operation
(temperature within permissible limits).

Remedy 1: Check whether the green LED is illuminated, if not, check power supply.
Remedy 2: Check whether resistance thermometer supply cable is damaged.
Remedy 3: Check whether measured values emitted by resistance thermometer are

correct (basic values of precision resistors in accordance with DIN 43760
for Pt 100).

Fault:

The testing with the switch

TEST

II /

INSPECTION

was not successful, i. e.

only one or neither of the red LEDs illuminates within two minutes
from the start of the test.

Remedy:

Replace temperature switch.

If faults occur that are not listed above please contact our subsidiary or agency in
your country.

Annex

Fault finding list for troubleshooting

Danger

The terminal strip of the TRS 5-6 b, TRS 5-6 c/d is live during operation.
This presents the danger of electric shock. Cut off power supply before
fixing or removing the cover.

4

1

2

1

2

1

2

3

3

4

Advertising