Technical data

Type approval no.
NRS 2-40: TÜV · WR · 98-399

Input / Output
Interface for CAN bus to DIN ISO 11898 using CANopen

Output – voltage supply for electrodes
Power supply 24 V DC, short-circuit protected
Analogue output 4 – 20 mA, load 500

for display of actual value (optional).

4 volt-free relay contacts.
Max. contact rating with switching voltages of 24 V AC,
115 V AC and 230 V AC: 4 A resistive, 0.75 A inductive at cos

ϕ

0.5

Max. contact rating with a switching voltage of 24 V DC: 4 A.
Contact material: silver, hard-gold plated

Interference suppression
Provide contactor with an external RC combination (100

/ 47nF)

Relay de-energizing delay
Output “MIN”, “MAX” 3 s

Indicators and adjustors
1 red LED for switchpoint “High level” (MAX)
1 red LED for switchpoint “Low level” (MIN)
2 green LEDs for switchpoints “PUMP ON” and “PUM OFF”
1 green LED “Power”
1 red LED “Bus fault”
1 ten-pole code switch for node ID and baud rate settings
4 pushbuttons

Supply voltage
230 V ± 10 %, 50/60 Hz
115 V ± 10 %, 50/60 Hz (option)

Power consumption
10 VA

Protection
Case:

IP 40 to DIN ISO 60529

Terminal strip: IP 20 to DIN ISO 60529

Admissible ambient temperature
0 °C to 55 °C

Enclosure material
Front panel: polycarbonate, grey
Case:

polycarbonate, black

Weight
Approx. 0.8 kg