Break-in procedure, How to use your unit – Delta OIL-FREE AIR COMPRESSOR CP503 User Manual

Page 13

Advertising
background image

13- ENG

A08200

Before Starting

Break-in Procedure

Serious damage (for units with a tank) may result if the
following break-in instructions are not closely followed.

This procedure is required

before the air compressor is put into service and

when the check valve or a complete compressor pump has been replaced.
1. Make sure the On/Auto/Off lever is in the "OFF" position.
2. Plug the power cord into the correct branch circuit receptacle. (Refer to

Voltage and Circuit Protection paragraph in the Installation section of this
manual.)

3. Open the drain valve fully (counterclockwise) to permit air to escape and

prevent air pressure build up in the air tank during the break-in period.

4. Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will

start.

5. Run the compressor for 15 minutes. Make sure the drain valve is open and

there is minimal air pressure build-up in tank.

6. After 15 minutes, close the drain valve (clockwise). The air receiver will fill

to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.

How to Use Your Unit

How to Stop:
1. Set the On/Auto/Off lever to "OFF".

Before Each Start-Up:

1. Place On/Auto/Off lever to "OFF".
2. Pull regulator knob out, turn counterclockwise until it stops. Push knob in

to lock in place.

3. Attach hose and accessories.

NOTE: The hose or accessory will require a

quick connect plug if the air outlet is equipped with a quick connect
socket.

Too much air pressure causes a hazardous risk
of bursting. Check the manufacturer’s maximum

pressure rating for air tools and accessories. The regulator outlet
pressure must never exceed the maximum pressure rating.