OBSERVED PROBLEM

Burner plaques do not light after ODS/pilot
is lit

Delayed ignition of burner plaques

Burner backfiring during combustion

POSSIBLE CAUSE

1. Burner orifice(s) is clogged

2. Burner orifice(s) diameter is too small
3. Inlet gas pressure is too low

1. Manifold pressure is too low
2. Burner orifice(s) is clogged

1. Burner orifice(s) is clogged or damaged

2. Inlet gas pressure is too low
3. Burner damaged
4. Gas regulator defective

REMEDY

1. Clean burner orifice(s) (see Cleaning

and Maintenance, page 11) or replace
burner orifice(s)

2. Replace burner orifice(s)
3. Contact local natural gas company

1. Contact local natural gas company
2. Clean burner orifice(s) (see Cleaning

and Maintenance, page 11) or replace
burner orifice(s)

1. Clean burner orifice(s) (see Cleaning

and Maintenance, page 11) or replace
burner orifice(s)

2. Contact local natural gas company
3. Replace burner
4. Replace gas regulator

1. Plaque damaged
2. Inlet gas pressure is too low
3. Control knob set too low

1. Residues from manufacturing processes

1. Metal expanding while heating or con-

tracting while cooling

Burner plaques do not glow

Slight smoke or odor during initial opera-
tion

Heater produces a clicking/ticking noise
just after burner is lit or shut off

TROUBLESHOOTING

Continued

1. Replace burner
2. Contact local natural gas company
3. Turn control knob to higher setting

1. Problem will stop after a few hours of

operation

1. This is common with most heaters. If

noise is excessive, contact qualified ser-
vice person

Continued