Error codes are displayed by the 7-segment display with “E” or “ER” plus the error number.

Error

message

Description

Possible error

reason

Troubleshooting

“flash”

Permanent use of keys;
Control unit cuts off after
10 sec

Water or cooking
utensils on the glass
above the control
unit

Cleaning of the
operational surface

Er 22

Defective Key
evaluation.
Control unit cuts off after
3.5 – 7.5 sec.

Short-circuit or
discontinuation in
the range of the key
evaluation

Exchange control unit

Er20

Flash-failure

µC- faulty

Exchange control unit

Er36

NTC value is not within
its specification (value <
200mV or > 4.9V; control
unit cuts off

Short-circuit or cut-
off at NTC

Exchange control unit

Er31

Configuration data
incorrect

Configuration of
induction necessary

New Configuration

Er47

Communication error
between TC and
induction

None or faulty
communication!

Ensure that
connection cable is
plugged on correctly
and functional.

E2

Overheating of the
induction coils

Cooling down
necessary

U400

Secondary voltage
of the power unit to
high (primary > 300V).
Control unit cuts off
after 1 sec releasing a
permanent tone.

Control unit is
wrongly connected.

Connect to correct
mains voltage

E5

Error on filter board

Exchange filter board

E6

Error on power unit

Exchange power unit

E9

Coil temperature sensor
defective

Exchange temperature
sensore