Factory presets, Factory settings, defaults, List of trigger signals – Dynacord DMM 4650 User Manual
Page 36

FACTORY PRESETS
The installed software v 1.2 provides pre-stored factory presets for sequences, alarms and gongs. Also
defined are basic settings (menu “System setup”) as well as input and output lines. For direct use of these
presets, installation examples are to be found on page 31.
Factory settings, defaults
The user can edit these defaults according to individual requirements.
The data of the menus “outputs” “standby” and “sum level” determines the status of the DMM 4650 in
stand-by mode (no sequence running). A running sequence could lead to a modification of the outputs.
Upon completion of the sequence, the outputs are switched back to their previous status (stand-by mode).
Menu
Parameter 1
Parameter 2
Parameter 3
Parameter 4
Contrast
0%
Backlight
50%
Phones
75%
Priority
Prio1 33
Prio2 66
Prio3 99
Password
Prio1 1111
Prio2 2222
Prio3 3333
Outputs
all Low (relay open), except B4 = High
Bypass
off (relay open)
Sum Gain
0 dB
Attenuation
alarms 0dB
gongs 0dB
messages 0dB
announcements 0dB
Language
German
RS 232
9600 Baud
List of trigger signals
Input Level
Delay
sec.
Trigger
type
starts
sequence
utilization
Function (see sequence)
A1
Off
release, S21 to S25, S31 and S33 to S37 wait for High at A1, return message
for system ready, upon release the signal output starts
A2
high
>00,1
dyn
S20
stops each running sequence
A3
high
>00,1
dyn
S21
start alarm message M00
A4
high
>00,1
dyn
S22
start DIN alarm, pulse trigger
B1
high
>00,1
dyn
S23
start DIN alarm, high = start, low = stop,
B2
high
>00,1
dyn
S24
start alarm text sequence, high = start, low = stop,
B3
high
>00,1
dyn
S25
4-tone gong, pulse trigger
B4
high
>00,1
dyn
S26
Pre-gong (2-tone), pulse trigger
C1
high
>00,1
dyn
S27
start message M01, pulse trigger
C2
high
>00,1
dyn
S28
start message M02, pulse trigger
C3
high
>00,1
dyn
S29
remote recording M01, pulse trigger, first pulse = start, second pulse = stop
C4
high
>00,1
dyn
S30
remote recording M02, pulse trigger, first pulse = start, second pulse = stop
D1
high
>00,1
dyn
S31
start DIN alarm with announcement key at D2, pulse trigger
D2
Off
announcement in S31, high = announcement, low = alarm
D3
high
>00,1
dyn
S32
start announcement DMM 4650 Mic, high = start, low = stop
D4
high
>00,1
dyn
S36
Morse key