Groth 8170 User Manual
Operation, Maintenance, Notice
 
INSTALLATION, OPERATION, AND MAINTENANCE 
GROTH MODEL 8170 MANOMETER 
 
INSTALLATION:
1. Mount manometer panel on wall
or other suitable support.
2. Connect pressure sensing lines
to
manometer
wells
with
enclosed plastic tubing or 1/4" 
copper tubing. 
3. Fill with indicating fluid with
specific
gravity
of
1.0
by
removing pressure connection. 
Set scale adjustment to zero. 
OPERATION:
Periodically vent manometer well to 
atmosphere and adjust zero point if 
required by adjusting scale or 
adding fluid. 
MAINTENANCE:
Clean tubes and indicator scale as 
required. 
Check
pressure
connection for leaks.
NOTICE:
Please specify model number, 
serial number and size as shown on 
the equipment tag when ordering 
replacement parts. 
(.281) DIA HOLE THRU
2 PLC'S (MOUNTING)
RANGE
NOTE: MAX DEPTH IS 1.50".
0 - 20
0 - 16
0 - 12
0 - 8
0 - 24
0 - 36
RED OIL
32.13
27.00
21.88
16.75
37.19
51.25
A
WATER
27.56
23.50
19.38
15.19
32.88
43.13
"A"
2.75
.75
3.56
GAGE CONNECTOR
SHUTOFF TYPE
3/16" RUBBER TUBING
IOM 8170.0
November 1994