3308120.XXX GENESIS AIR FILTRATION SYSTEM

OPERATING

INSTRUCTIONS

1.

GENERAL INSTRUCTIONS

A. Read your Control Systems Operating Instructions care-

fully before attempting to start your air conditioner.

B. The 3308120.XXX Genesis Air Filtration System is

designed to allow the unit to direct the air flow through the
RV’s duct system; or, by opening a slide control the air
will be discharged directly out from the return air cover.
1. Slide the slide handle towards the front of the RV to

divert the air into the duct system.

2. Slide the slide handle to the rear of the RV and the air

will discharge out the return air cover.

G. Use Aluminum foil tape (not provided) to seal the ends of

the foam divider to the sides of the opening. Make sure
the area behind the flange on the ceiling template is

sealed. See Figure 9.

FIG. 9

Use Aluminum Foil Tape To Seal the
Foam Divider To The Sides of 14-1/4"
x 14-1/4" (±1/8") Ceiling Opening

Make Sure To Seal
Behind Flange

Route wires
through Slot

Catch Flange In Groove Of
Return Air Cover

H. Install the slider in the return air cover and raise it to the

ceiling template. Route the wires from the return air
cover through the template slot leaving about 3” of wire
in between. Place the front of the return air cover against
the ceiling and slide towards the rear. The flange on the
ceiling template will catch in the groove on the return
cover. Adjust the position (right to left) and install the
front two screws. Start and tighten the remaining screws
to hold it in place. Connect together the DC wires (3
Black - negative and 3 Red - positive) from the supply,
control box and filter indicator. See figure 9.

Note: Number 10 cabinet screw can be used to replace
the two front screws, and pull the plastic return air cover
to the ceiling when the ceiling material is hard.

1. If solar panel is installed see instructions pack

aged with solar panel option.

I.

Tighten the screws holding the return air cover. Slide the
filter from the right side (looking toward the RV front) over
the wires. Make sure the wires are above the filter and are
out of its way.

J.

Place grill on return air cover and snap in place. Decal is
on end over circuit board.

K. Place slide handle through slots in grill into the slide

posts. Handle will fit in either direction. See Figure 10.

C. The “CLEAN FILTER” bulb will blink as a reminder to

clean/change the air filter every 60 days. If in dusty
conditions, the filter should be checked bi-weekly and
clean/changed if needed.
1. To clean the filter, remove the dust using a vacuum
cleaner. Wash filter with a mild detergent, rinse with
clean water and allow to dry.
NOTE: Replace filter annually. See your Duo Therm
Dealer for replacement filter. Filter part numbers are
stamped on filter frame.

2.

To reset the “CLEAN FILTER” reminder:
a. Depress the gray button “FILTER RESET” on the

decal of the grill. The Light will blink 3 times to indicate
a successful reset. See Figure 11.

Micro-Therm Filter System

Micro-Therm Filter System

FILTER
RESET

FILTER
RESET

CLEA

N

FILTE

R

CLEAN
FILTER

Micro-Therm Filter System

Micro-Therm Filter System

FILTER
RESET

FILTER
RESET

CLEA

N

FILTE

R

CLEAN

FILTER

FIG.11

Push To Reset

Light

Micro-Therm Filter System

Micro-Therm Filter System

FILTER
RESET

FILTER
RESET

CLEA

N

FILTE

R

CLEAN
FILTER

Ceiling
Template

Foam
Divider

Slide

Filter

Return
Air
Cover

FIG. 10

Grill

Slide
Handle

Advertising