ArcGlide THC Instruction Manual 806450

1 – Specifications

Ethernet switch

If the ArcGlide THC has more than one connection to Hypernet that communicates with either the CNC or the plasma
system, you must include an industrial grade Ethernet switch with multiple ports for communication between these
components.

This switch must be an industrial grade switch that supports shielded Cat5e

or Cat6

Ethernet cable. The Ethernet

switch should be located in an electrical cabinet that is electrically grounded and environmentally clean.

A plasma arc cutting machine can be configured with the following units:

1 CNC with Hypernet support

Up to 4 plasma systems

4 ArcGlide THC control modules

4 ArcGlide THC lifters

4 ArcGlide TNC HMIs

The total number of Ethernet ports the system requires depends on the number of plasma systems and ArcGlide THCs
installed. Use

Table 2 to help determine the number of Ethernet ports the system needs.

Table 2

For example, a cutting machine with 2 plasma systems + 2 THCs + 2 HMIs + 1 CNC = 7 ports.

Hypernet connections and Ethernet connections to a LAN cannot be made through the same switch. If your cutting
machine is connected to a LAN over Ethernet, you must use a separate Ethernet switch for these connections.

Hypertherm recommends 3

different models of

Advantech™ industrial Ethernet switches. These switches

are available

from Hypertherm.

Table 3 provides details about each model.

Choose the switch that fits your needs.

For each of these components:

You need this many Ethernet ports:

CNC

1

Plasma system (1 to 4) + lifter (1 to 4)

2 to 8

Plasma system (1 to 4) + lifter (1 to 4) + HMI (1 to 4)

3 to 12