SPECIFICATIONS

Power Supply

• Place the power supply in an area that is free of excessive moisture, has proper ventilation, and is relatively

clean. Allow room at the sides and rear of the power supply for servicing.

• Cooling air is drawn in through the front panel grating and is exhausted through the rear of the unit by a

cooling fan. Allow a minimum of 12 inches (305 mm) for air flow.

• Maximum distance to the ignition console = 150 feet (46 m).

• Maximum distance to the gas console = 150 feet (46 m).

General

Maximum OCV (U

0

)

311 VDC

Maximum Output Current (I

2

)

200 amps

Output Voltage (U

2

)

85 - 200 VDC

Duty Cycle Rating (X)

100% @ 40 kw, 104°F (40°C)

Ambient Temperature/Duty Cycle

Power supplies will operate between +14° and 104°F
( -10°C and +40°C)

Power Factor(cos

ϕ

)

0.98 @ 200A DC output

Cooling

Forced Air (Class F)

Input Power (Input Voltage (U

1

) X Input Current (I

1

X 1.73)

200 VAC, 3ph, 50-60 Hz, 125A

220 VAC, 3ph, 50-60 Hz, 113A

240 VAC, 3ph, 60 Hz, 103A

400 VAC CE, 3ph, 50-60 Hz, 62A

440 VAC, 3ph, 50-60 Hz, 56A

480 VAC, 3ph, 60 Hz, 52A

600 VAC, 3ph, 60 Hz, 41A