background image

MAX200

Product Configuration Manual

2-2

Programmable

Remote V/C

CNC

Interface

(customer

supplied)

Torch

WM

IHS

Console

Air Reg.

Second

MAX200

Power
Supply

WM

Pump

Digital

Remote V/C

Switch

Remote V/C

Remote
Current

Control

MAX200

Power
Supply

1

MAX200 Power Supply (PS)

2

Machine Torch Assembly

3

Leads Between Power Supply and Torch

4

Machine Interface Cable Between Power Supply and
CNC Interface

5

Programmable Remote Voltage & Current Control

6

Cable Between Power Supply and Programmable Remote or
Digital Remote

7

Cable Between Programmable Remote and CNC Interface

8

Digital Remote Voltage & Current Control

9

Switch Remote Voltage & Current Control

10

Cable Between Power Supply and Switch Current

11

Remote Current Control

12

Cable Between Power Supply and Current Remote

13

Inductive IHS System

14

IHS Pressure Regulator Assembly

15

Inductive IHS Lead Set

16

Water Muffler System

(not used with the stainless steel torch)

17

Additional Length WM Hose

18

Cable Between Water Muffler Pump and Power Supply

19

Work Cable Between Power Supply and Work Table

20

Hold Cable Between Power Supplies

MAX200 Machine System Block Diagram