MAINTENANCE AND PARTS

2

powermax30

Operator Manual

5-11

9. To replace the endcap, push it into the base to re-engage the snaps and then replace the

retaining screw.

10. Replace the Nomex barrier and slide the cover back onto the power supply.

11. Position the handle over the holes in the top of the cover, then use the 2 screws to secure the

cover.

12. Reconnect the electrical power and the gas supply.

Disconnect the torch lead

1. Turn OFF the power, disconnect the power cord, and disconnect the gas supply.

2. Remove the cover and remove the Nomex® barrier from in front of the power board.

3. Compress the hose fitting collar and pull the hose from the fitting to remove the gas hose from

the solenoid valve.

Front endcap

Solenoid valve

Hose fitting collar

Gas hose

White wire group

Red wire group

PMX30_OM_05.qxp:PMX30_OM_05 10/7/09 12:46 PM Page 5-11