IDK MSD-54 Series Command Guide User Manual

Page 98

Advertising
background image

MSD-54 Series Users Guide (Command Guide)

98

@GEC

Get control command (Control Tally output)

Command format

@GEC, no

Return value
format

@GEC, no, delay, port, memo, pinno_1, out_1, pulse_1 (, pinno_2, out_2,
pulse_2, pinno_3

, out_3, pulse_3・・・)

Parameter

no

: Command number

1 to 32

delay

: Delay time

0 to 999999

port

: Tally output control

Specify 2048 for Tally output control.

memo

:

Up to 14 characters of 20 to 7D except 2C (,). “2 ASCII codes”

pinno_1-6

: Pin number

22 to 24, 47 to 49

out_1-6

: Control output pin

0 = OFF, 1 = ON, 2 = TOGGLE

pulse _1-6

: Pulse width

0, 100 to 9990

Send settings of pins you want to control.

Example Send

Receive

@GEC,5

@GEC,5,20,2048,SCREEN
UP, 22,1,100

Get control command 5.
・

Control after 20 ms.

・

Memo: SCREEN UP

・

Tally output pin 22 is ON for 100
ms.

・

All other pins are not controlled

Send

Receive

@GEC,6

@GEC,6,50,2048,PROJEC
TOR ON,22,0,200,23,1,0

Get control command 6.
・

Control after 50 ms

・

Memo: PROJECTOR ON

・

Tally output pin 22 is OFF for 200
ms.

・

Tally output pin 23 is ON and the
ON state is kept.

・

All other pins are not controlled.

Related info.

8.12.1 Control commands