INSTALLATION AND CONNECTION

PART 2 INSTALLATION AND CONNECTION

®

GW_40TM09

www.insingermachine.com 800-344-4802

Connection to the Drain:
The unit is equipped with a 2” OD drain connection

and must be connected to drain capable of handling

a 9.0 gal/min fl ow. A proper air gap must be supplied

between the unit and the building drain connections.

Failure to provide air gap will result in improper or

inconsistent draining of unit and potential overfl ow

condition.

Connection to the Power Supply:
Electrical and grounding connections must comply

with all applicable portions of the National Electric

Code (ANSI/NFPA 70) and/or other electrical codes

that may apply.
The unit is 115 volts and the total amp load is 14

fl a for the washer without the optional maintenance

heater and 16.0 fl a for the washer with the optional

maintenance heater. The unit is internally wired so

that the wash pump and the optional maintenance

heater do not operate at the same time.

Check for Completeness:
After unpacking the machine, fi rst check the delivery

against the packing slip to ensure that it is complete,

and inspect for damage that may have occurred

during transportation. Immediately report any

damage to the carrier, the insurance company and

the manufacturer.

Setting Up and Alignment:
When setting up the machine, remember that the

machine gives off steam during operation (when you

open the door). Protect adjacent wooden furniture to

prevent it absorbing moisture and swelling.

The machine must be completely level when in-

stalled. Adjust the machine’s feet to compensate for

any unevenness of the fl oor.

Connection to the Water Supply:
All plumbing connections must comply with all

applicable local, state, and national plumbing codes.

Flush the incoming water supply to remove all foreign

debris prior to connecting to the unit.
Connect the hot water (120°F minimum) supply

hose (1/2”IPS) from the fi ll solenoid valve located

behind the front panel on the right side to the

building water supply. Recommended installation

includes the use of a ball valve (supplied by others).

A pressure regulator (supplied by others) is required

if the water pressure fl uctuates or is greater then the

recommended pressure (22psig). The unit has a built

in air gap. A vacuum breaker is not required.

CAUTION:

Protect the washer against frost. Systems that carry

water can be damaged if they freeze.

CAUTION:

Note all the information on the enclosed connection

diagram. For the machine to work correctly, the required

water pressure and fl ow rate must be

guaranteed at all times.

WARNING:

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow-these instructions can
result in death, fi re, or electrical shock.

!