7. Check if rinse pressure is approximately 20 psi. Note: This must be checked during rinse cycle only for

accurate reading.

8. Make sure steam exhaust fan is working properly. On machines with a 100cfm Tjernlund fan, the fan

should run continuously when power switch is turned on. On machines with a 700 cfm American fan,
the fan should run for set amount of time after the rinse cycle.

9. * Allow machine to heat up to recommended temperatures, noting if temp gauges and thermostats are

operating properly (see start up procedure in owners manual for approximate heat up times). Wash
temperature and Rinse Tank temperature should be noted at this time. The rinse water temperature
gauge is accurate only during rinse cycle and should be checked while machine is rinsing.

10. Note: If a qualified technician is available, current readings for heating elements should be taken to

ensure they are heating properly.

11. On machines with slideup doors, door cables and connections should be inspected for damage or

excessive wear and replaced if necessary. Make sure cable pulleys turn freely and door switch is still
adjusted properly.

12. Pump motor(s) should be greased occasionally depending on usage. Once or twice yearly should be

sufficient under normal use.

Note:

Items above marked * are easily identified visually and should be checked on a daily basis. Other items
should be checked periodically, depending on usage.
Time required for complete inspection may vary, depending on wash timer settings, heat up time, etc. One
to two hours is a reasonable amount of time unless problems are encountered that need attention. If any
problems or questions arise, call the factory for assistance.