EXTENSION CORDS

Use proper extension cords. Make sure

your extension cord is in good condition and is a 3-wire
extension cord which has a 3-prong grounding type
plug and matching receptacle which will accept the
machine’s plug. When using an extension cord, be sure
to use one heavy enough to carry the current of the
machine. An undersized cord will cause a drop in line
voltage, resulting in loss of power and overheating. Fig.
D-1 shows the correct gauge to use depending on the
cord length. If in doubt, use the next heavier gauge. The
smaller the gauge number, the heavier the cord.

Fig. D-1

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

Ampere

Total Length

Gauge of

Rating

Volts

of Cord in Feet

Extension Cord

0-6

120

up to 25

18 AWG

0-6

120

25-50

16 AWG

0-6

120

50-100

16 AWG

0-6

120

100-150

14 AWG

6-10

120

up to 25

18 AWG

6-10

120

25-50

16 AWG

6-10

120

50-100

14 AWG

6-10

120

100-150

12 AWG

10-12

120

up to 25

16 AWG

10-12

120

25-50

16 AWG

10-12

120

50-100

14 AWG

10-12

120

100-150

12 AWG

12-16

120

up to 25

14 AWG

12-16

120

25-50

12 AWG

12-16

120

GREATER THAN 50 FEET NOT RECOMMENDED

FUNCTIONAL DESCRIPTION

FOREWORD

Model 50-875 Delta Air Cleaner is specifically designed to quietly circulate and filter non-metallic dust which is
generated throughout the work area. The Air Cleaner is furnished with two filters: an outer filter which filters particles
that are five microns and larger, and a secondary disposable filter that captures 91% of the dust particles that are one
micron and larger (one micron = one millionth of a meter). Because breathing microscopic particles can be a potential
health hazard, filtering microscopic dust particles offers a cleaner and safer environment. This Air Cleaner will filter the
air in a room measuring 20’ x 20’ x 8’ either 13, 16, or 18 times an hour, depending on the setting. If desired, multiple
units can be used to filter larger areas. An occasional cleaning and/or replacement of filters is the only required
maintenance.

Fig. 1A

1

Fig. 1B

1.

Air cleaner

2. Remote Control Unit

(Batteries not included)

3. 1” Eye-Bolts (4)
4. Rubber Feet (4)
5. 1/4-20 Flange Nuts (4)

CARTON CONTENTS

5

2

3

4

5

Advertising