Kemppi Kempact Pulse 3000 User Manual
Page 18

EN
3.3.12 SETUP
Using the SETUP function, the user can change welding parameters which do not have their
own panel functions. These parameters can be set separately for 1-MIG and Pulse MIG. SETUP
settings are separate for each memory channel.
Setup functions on pulse panel
Parameter Name Nr Display
1-MIG
Pulsed
MIG
Factory
value
Unit
Explanation
PostGasTime
1
PoG
X
X
Curve
s
PostGas time 0.0 – 9.9 s
PreGasTime
2
PrG
X
X
Curve
s
PreGas time, functions by 2T
0.0 – 9.9 s
HotStartLevel
11
Hot
X
X
30
%
Hot start ratio to welding power
-50 ... +75%
HotStartTime 2T
12
H2t
X
X
1.2
s
2T Hot start timer 0.1 – 9.9 s
CraterFillLevel
14
CFL
X
X
30
%
Welding end level 10 – 90 %
CraterFillSlope
15
CFS
X
X
1
s/10m
Wire slowing-down
1 – 20 s/10m
CreepStartLevel
17
CSL
X
X
Syn
Wire speed start value 10 – 90
CreepStartSlope
18
CSS
X
X
0
s/10m
Wire speed up time
0 – 50 s/10m
DoubleFrequency
21
dFr
X
Curve
Hz
Double pulse frequency control
0.4 – 8.0 Hz
DoubleAmpiltude
22
dA
X
Curve
m/min Double pulse power variation
control 0.1 – 3.0 m/min
StartPower
31
StP
X
X
0
Start power control
-9 ... 0 ... +9
PulseCurrent
33
PuC
X
0
%
Pulse top current control
-10 ... +15%
ArcLength
AdjRange
41
ALr
X
X
0
%
Arc length adjustment range
-50 ... +75%
Calibration
42
CAL
X
X
1
V/100A Setting mid value of arc length
fine adjustment
0.0 – 10.0 V/100A
WFS
51
FS
18
m/min Wire feed maximum
18 or 25 m/min
Gun
53
Gun
On
Liquidcooled thermal protection
on/off
GunRemote
54
GrE
On
Disabling of gun remote control
automatic identification
Water Cooler
On/Off Selection
55
Coo
On
Set OFF after each power up if
cooler is connected with gas
cooled gun.
Display reset time
81
dLY
X
X
5
s
1 – 20 s
PRG INFO - feeld
selection
82
diS
X
X
1
1, 2, 3
Restore
99
FAC
X
OFF
Restoring factory settings
(OFF=no reset,
Pan=panel and setup
ALL= also memory channels)
16
Kempac
t P
ulse 3000, Kempac
tC
ool 10 / © Kemppi O
y / 1136