8 setup functions, 2 pilot lamps, 3 operation of cooling fan – Kemppi KMS 400 AS User Manual

Page 11

Advertising
background image

EN

WiseRoot process for root pass welding and then completing hot pass and filler runs with

ArcFeed system using self-shielded filler wire.
MMA welding
FastMig KMS AS is also suitable for MMA welding with basic or rutile electrodes. MMA welding

works with CC (Constant current) mode set from the AS power source panel.

NOTE!

In CC/MMA mode FastMig KMS AS has two welding programs: one for ArcFeed CC welding

and the other for MMA welding. The desired welding program can be chosen from the KMS AS

‘SETUP’ function.

TIG welding
By connecting MasterTig LT 250 to FastMig M with AS panel, TIG welding can be done. You

must select either CC or CV (Constant Current or Constant Voltage) mode from the AS control

panel.

2.8 Setup functions

With a long press of the SETUP button you can move to the Setup menu

Start Power

StA

-9 ... +9

0

Strength of start pulse

Device address

Add

3 or 6

6

System bus address. Each device in same system
must have different address.

Welding program CC/MMA

Pro

Stl, FEE

StI is for MMA welding FEE is for ArcFeed

Welding program CV

Pro

Std, InS

InS is for innershield wires Std for other wires

Restore factory settings

FAC

OFF, PAn, ALL OFF

Restores factory settings, when PAn or ALL is
selected

Remote control

rc

OFF, on

OFF

Manual control / remote control unit selection

3.

OPERATION CONTROL SWITCHES AND POTENTIOMETERS

3.1 Main switch I/O

When you turn the switch into I-position, pilot lamp H11 on the front face is illuminated and

the machine is ready for use.

NOTE!

Always turn the machine on and off with the mains switch, never use the mains plugs as a

switch.

3.2 Pilot lamps

The pilot lamps of the machine report the electric operation:
The green pilot lamp H11 when lit indicates that the machine is on and ready for use and it is

connected to the mains supply with the main switch in the I-position.
H12 indicates when lit that the thermal protection of the machine has been activated due to

over heating. The cooling fan will continue to run and cool the machine down and when the

lamp is off the machine is ready to weld.

3.3 Operation of cooling fan

In FastMig KMS 400 AS power source there is two simultaneously operating fans.

• The fan is started for a moment when main switch is placed into position I.

• The fan will start during welding as the machine heats up and it will run for 1 to 10

minutes after the welding has stopped.

9

© Kemppi Oy / 1515

Advertising