12 en, Technical data – Kemppi M 420MV User Manual

Page 14

Advertising
background image

FastMig M 420MV

12

EN

9.

TECHNICAL DATA

FastMig™ M 420MV

230 V range

400 V range

Connection voltage

3~, 50/60 Hz

220 V -10 %...230 V +10 % 380 V -10 %...440 V +10 %

Rated power

60% ED

21 kVA

22 kVA

100% ED

18 kVA

19 kVA

Connection cable

H07RN-F

4G6 (5 m)

4G6 (5 m)

Fuse (delayed)

50 A

35 A

Output 40 °C

60 % ED

420 A

420 A

100 % ED

380 A

380 A

Welding current and voltage range

MMA

15 A/20 V...420 A/48 V

15 A/20 V...420 A/44 V

MIG

20 A/12 V...420 A/48 V

20 A/12 V...420 A/44 V

Max. welding voltage

48 V

44 V

Open circuit voltage

MMA

U

0

= 48...53 V

U

av

= 50 V

U

0

= 48...53 V

U

av

= 50 V

MIG/MAG

U

0

= 60...65 V

U

0

= 53...58 V

Idle power

25 W

25 W

Efficiency at max. current

87 %

87 %

Power factor at max. current

0.85

0.82

Operating temperature range

-20...+40 ºC

-20...+40 ºC

Storage temperature range

-40...+60 ºC

-40...+60 ºC

Degree of protection

IP23S

IP23S

EMC class

A

A

Minimun short circuit power Ssc of
supply network*

N/A

5.6 MVA

External dimensions

L x W x H

590 x 230 x 580 mm

590 x 230 x 580 mm

Weight

49 kg

49 kg

Voltage supply for auxiliary devices

50 V DC

50 V DC

X14, X15

fuse 6.3 A delayed

fuse 6.3 A delayed

Operating voltage
(for cooling unit)

380 V -10 %...440 V +10 % 380 V -10 %...440 V +10 %

* See paragraph 2.2.

Advertising