Kemppi Kempomat 2500 User Manual

Page 16

Advertising
background image

EN

4.4

main switChes and pilOt lamps

main switch (Kempomat 2500 and 3200)

In zero position all control and welding current circuits of the equipment are dead (without

voltage). In position I the control circuits of the machine become live (get voltage). The

primary and welding circuits are dead, if the welding mode has not been started with the gun

trigger.

main switch (Kempomat 4200)

In zero position all control and welding current circuits of the equipment are dead (without

voltage). In positions 15 - 28 V and 28 - 48 V the control circuits and cooling fan of the

equipment get voltage. The primary and welding circuits are dead, if the welding mode has

not been started with the gun trigger.
Always switch on and switch off the machine from the main switch. Never use the mains plug

for switching on or switching off the units and equipment!

adjustment of welding voltage

Table of adjustments, switch positions:
In Kempomat 2500 the welding voltage is adjusted with one 10-step turn switch. In

Kempomat 3200 and 4200 the welding voltage is adjusted with two turn switches. In

Kempomat 4200 first select the other welding voltage area from the main switch . There

is 4-step switch for coarse control, where voltage value of each step can be fine-adjusted

with the switch . The switch for fine-adjustment in Kempomat 3200 is with 10-steps, in

Kempomat 4200 230V with 4-steps, and in Kempomat 4200 400V with 7-steps.

Kempomat 2500

Kempomat 3200

Voltage step

Open circuit

voltage

Coarse control

Fine control

Open circuit

voltage

1

13.7 V

1 / 4

1 / 10 – 10 / 10

15.5 – 18.2 V

2

15.2 V

2 / 4

1 / 10 – 10 / 10

18.6 – 22.5 V

3

16.9 V

3 / 4

1 / 10 – 10 / 10

23.1 – 29.3 V

4

18.8 V

4 / 4

1 / 10 – 10 / 10

30.4 – 41.6 V

5

20.8 V

6

23.0 V

7

25.5 V

8

28.3 V

9

31.4 V

10

34.9 V

Kempomat 4200
Main switch.

Coarse control

Fine control

(400V)

Fine control (230V) Open circuit

voltage

15 – 28 V

1 / 4

1 / 7 – 7 / 7

1 / 4 – 4 / 4

14.6 –16.3 V

15 – 28 V

2 / 4

1 / 7 – 7 / 7

1 / 4 – 4 / 4

16.6 – 18.8 V

15 – 28 V

3 / 4

1 / 7 – 7 / 7

1 / 4 – 4 / 4

19.2 – 22.0 V

15 – 28 V

4 / 4

1 / 7 – 7 / 7

1 / 4 – 4 / 4

22.5 – 26.1 V

28 – 48 V

1 / 4

1 / 7 – 7 / 7

1 / 4 – 4 / 4

27.1 – 30.0 V

28 – 48 V

2 / 4

1 / 7 – 7 / 7

1 / 4 – 4 / 4

30.5 – 34.2 V

28 – 48 V

3 / 4

1 / 7 – 7 / 7

1 / 4 – 4 / 4

34.9 – 39.7 V

28 – 48 V

4 / 4

1 / 7 – 7 / 7

1 / 4 – 4 / 4

40.5 – 47.1 V

14

Kempoma

t 2500, 3200, 4200 / © Kemppi O

y / 1117

Advertising
This manual is related to the following products: