seTup-FunCTiOns

SETUP-function

Display

*C = Common: applies to all memory channels

Factory setting with a grey background

Upslope current dependency

(*C)

A1

ON

The upslope time is determined by the current.

OFF

The upslope time remains as set.

Downslope current

dependency (*C)

A2

ON

The downslope time is determined by the current.

OFF

The downslope time remains as set.

TIG Antifreeze (*C)

A3

ON

TIG Antifreeze on.

OFF

TIG Antifreeze off.

MMA Antifreeze (*C)

A4

ON

MMA Antifreeze on.

OFF

MMA Antifreeze off.

VRD (*C)

A7

ON

VRD mode: idle voltage < 35 V

OFF

Normal idle voltage (3000: 63 V, 3003: 58 V)

2T downslope cut off

A8

ON

In 2T mode, cut off the downslope with a quick push of the start
button.

OFF

Quick push has no effect.

Tacking automatics

A9

ON

If welding has lasted less than 3 seconds, no downslope when
welding is stopped.

OFF

Tacking automatics off.

Limitation of rate of current

rise with high currents

A10

ON

If the current is over 100 A and UpSlope is 0.0 sec., there is a 0.2-
second slope from half the welding current.

OFF

Current rises directly to indstillet værdi.

MMA/TIG method selection

with remote control (C*)

A12

ON

TIG = the start of remote control scale.
MMA = the end of the scale.

OFF

Remote control as a normal current regulator.

SearchArc On/Off

A13

ON

SearchArc on.

OFF

SearchArc off.

Current freeze function

A14

ON

During the slope, the current can be ‘frozen’ at a certain level (4T
and Minilog) by pushing the start button.

OFF

Freeze function off.

Memory channel selection with

Plus/Minus buttons (C*)

A15

ON

The Plus/Minus buttons on the remote control RTC20 can be used
to select the memory channel.

OFF

The buttons adjust the current.

Activation of the Plus/Minus

buttons (C*)

A16

ON

The Plus/Minus remote control (RTC20) is always active.

OFF

The Plus/Minus remote control is active only when selected by
pressing the REMOTE button.

Water cooler flow guard (C*)

A17

ON

Flow guard on.

OFF

Flow guard off.

Water cooler automatic control

(C*)

A19

ON

Automatic control on.

OFF

Water cooler runs constantly.

Water cooler temperature

guard (C*)

A20

ON

Water cooler temperature guard selected.

OFF

Temperature guard off.

Automatic remote control

device recognition (C*)

A21

ON

Automatic recocnition on, control cannot be selected if it is not
connected.

OFF

Automatic recocnition On/Off. Controller can be selected even if it
is not connected.

Tail arc

A22

ON*

Tail arc on. * 4T LOG

OFF**

Tail arc off. ** MINILOG