EN

2.5

distriButiOn netwOrk

All regular electrical devices without special circuits generate harmonic

currents into distribution network. High rates of harmonic current may cause

losses and disturbance to some equipment.

Minarc 150, 150 Vdr, 120 au, 150 au

WARNING: This equipment does not comply with IEC 61000-3-12. If it is

connected to a public low voltage system, it is the responsibility of the

installer or user of the equipment to ensure, by consultation with the

distribution network operator if necessary, that the equipment may be

connected.
Does not apply to model Minarc 151.

2.6

COnneCting tO pOwer supply Mains

The unit has a mains cable and a wall plug (Note! Minarc 151 (110 V) is

delivered without a plug). You can find fuse and cable sizes in the end of

these instructions in Technical data.

2.7

Filler Materials and equipMent

See also 2.4 Main components. You can use all electrodes intended for

welding with DC. Suitable electrode sizes for the unit are listed in the end of

these instructions in Technical data.

1. Use welding specifications given on electrode package.

2. Check that you have selected the correct welding process before starting

to weld.

3. Check that welding cable and earth cable connections are tight. If a

connection is slack, it will result in voltage drop that will cause the

connection to heat.

4. Mount the electrode firmly in holder.

6

M

inar

c 150, 151 / © Kemppi O

y / 1117