GB

Electrical connections

Before connecting the oven to the mains power supply,

make sure that:

- The supply voltage corresponds to the specifications

on the data plate on the front of the oven.

- The mains supply has an efficient earth (ground)

connection complying with all applicable laws and

regulations. Correct earthing (grounding) is a legal

requirement.

The power cable should never reach a temperature 50°

C above ambient temperature at any point along its

The socket or switch must be easily reachable with the

oven fully installed.

N.B. The manufacturer declines all responsibility for

damage or injury if the above instructionsntinfortunistiche

non vengano rispettate.

CABLE TYPES AND MINIMAL DIAMETERS

SASO

H05RR-F 3x1,5 mm

2

H05RR-F 3x2,5 mm

2

H05VV-F 3x1,5 mm

2

H05VV-F 3x2,5 mm

2

H05RN-F 3x1,5 mm

2

H05RN-F 3x2,5 mm

2

H05V2V2-F 3x1,5 mm

2

H05V2V2-F 3x2,5 mm

2