Fireplace installation – Desa TC36N User Manual

Page 23

Advertising
background image

www.desatech.com

116192-01E

23

Figure 32 - Connecting Flexible Gas Line

to Millivolt Valve

Flexible Gas Line
Do NOT Kink

Equipment
Shutoff Valve

To Gas Supply
(Natural)

To External
Regulator
(Propane/LP)

Control Valve

FIREPLACE

INSTALLATION

Continued

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping

and connections, internal and

external to unit, for leaks after

installing or servicing. Correct

all leaks at once.

WARNING: Never use an open

flame to check for a leak. Apply

noncorrosive leak detection fluid

to all joints. Bubbles forming show

a leak. Correct all leaks at once.

PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)

1. Disconnect fireplace and its individual equip-

ment shutoff valve from gas supply piping

system. Pressures in excess of 1/2 psig (3.5 kPa)

will damage fireplace gas regulator.

2. Cap off open end of gas pipe where equipment

shutoff valve was connected.

3. Pressurize supply piping system by either

opening propane/LP supply tank valve for

propane/LP gas fireplace or opening main gas

valve located on or near gas meter for natural

gas fireplace or using compressed air.

4. Check all joints of gas supply piping system.

Apply noncorrosive leak detection fluid to all

joints. Bubbles forming show a leak. Correct

all leaks at once.

5. Reconnect fireplace and equipment shutoff

valve to gas supply. Check reconnected fittings

for leaks.

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Figure 33).

2. Pressurize supply piping system by either

opening propane/LP supply tank valve for

propane/LP gas fireplace or opening main gas

valve located on or near gas meter for natural

gas fireplace or using compressed air.

3. Check all joints from propane/LP supply tank

or gas meter to equipment shutoff valve (see

Figure 34, for propane/LP or Figure 35, for

natural gas). Apply noncorrosive leak detec-

tion fluid to all joints. Bubbles forming show

a leak. Correct all leaks at once.

Figure 33 - Equipment Shutoff Valve

Open

Closed

Equipment
Shutoff Valve

Figure 34 - Checking Gas Joints for

Propane/LP Gas Fireplace

Propane/LP
Supply Tank

Gas Valve

Equipment Shutoff Valve

Figure 35 - Checking Gas Joints for

Natural Gas Fireplace

Gas
Meter

Gas Valve

Equipment
Shutoff Valve

Advertising
This manual is related to the following products: