5

Tank Full
Float
Switch

SaniGard Vent

Filter

KEY SYSTEM COMPONENTS (cont'd)

SaniGard

Holding Tank Vent Filter:

The vent

filter stops odors that escape from the holding tank
vent. It contains odor-removing filter media to keep
your boat smelling clean and pleasant. Each cartridge
is good for an entire season and is easily replaced for
a fresh start.

"Tank Full" Float Switch:

The Tank Full Float Switch is mounted in top of the

holding tank or vent pipe, and shuts the vacuum pump or vacuum generator off when
the float switch is activated by the rising contents of the holding tank. This relay also
sends a signal to the status panel red light. This relay is prewired and mounted to the
pump on the vacuum generator. For systems using a vacuum tank and separate
pump, it is mounted separately during installation and wired accordingly.

SaniPump™ Discharge Pump:

For thorough, trouble-free holding tank

pump-out, our discharge pump offers many benefits. Its specially designed bellows
diaphragm allows it to run dry without harm. It handles up to 315 gallons (1192
liters) per hour, while drawing only 6 amps at 12 volts DC.
NOTE: On/Off switch for discharge pump is supplied by installer.

Discharge Hose:

Reinforced, 32 mm ID, 3-meter discharge hose. Includes

38 mm adapter to connect to discharge pump outlet.

Discharge
Hose

Discharge
Pump

1. Fill freshwater tank and add deodorant to holding tank through toilet bowl.
2. Make sure all guests understand the operation of the VacuFlush system and the instruction label is in plain

sight and easy for guests to read. If this label is not included in this manual, please contact Dometic’s
Customer Service Department immediately.

3. Remember the vacuum pump starts automatically.

Shut off the electrical power to the system before
servicing and do not leave the recreational vehicle
with toilet system breaker on.

4. Never use drain openers, alcohol, solvents, etc.

in the system.

5. If the system does not function properly, refer to the

Troubleshooting Section of this manual and repair
as necessary. If problem persists, contact your local
Dometic product dealer or see the Customer
Service section of this manual.

IMPORTANT INFORMATION BEFORE OPERATION

SYSTEM START-UP

1. Turn on electrical power to sanitation system.
2. Flush water into system by depressing flush lever on toilet until water starts flowing through the vacuum pump and

into the holding tank (blackwater tank). This wets the pump interior for efficient operation. If the vacuum pump
does not run, check for loose electrical connections. Refer to the system Wiring Diagram.

3. The vacuum pump will run for approximately 30 to 90 seconds until the system reaches operating vacuum level

and then will shut off.