Installation, Continued – Desa SL30NT/SL30PT User Manual

Page 10

Advertising
background image

111487-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

10

INSTALLATION

Continued

Figure 10 - Checking Gas Joints on Propane/LP Gas Unit

Control Valve Location

Propane/LP
Supply Tank

Equipment
Shutoff Valve

Pressure Testing Heater Gas Connections

1.

Open equipment shutoff valve (see Figure 9, page 9).

2.

Open main gas valve located on or near gas meter for natural
gas or open propane.LP supply tank valve.

3.

Make sure control knob of heater is in the OFF position.

4.

Check all joints from equipment shutoff valve to control valve
(see Figure 10 or 11). Apply noncorrosive leak detection fluid
to gas joints. Bubbles forming show a leak.

5.

Correct all leaks at once.

6.

Light heater (see Operating Heater, page 11). Check all other
internal joints for leaks.

7.

Turn off heater (see To Turn Off Gas to Appliance, page 11).

INSTALLATION

Checking Gas Connections (Cont.)
Installing Rod and Screen

Figure 11 - Checking Gas Joints on Natural Gas Unit

Gas Meter

Equipment
Shutoff Valve

Control Valve Location

INSTALLING ROD AND SCREEN

1.

Insert rod through small rings located at top of screen (see
Figure 12).

2.

From back of stove, insert rod into hole located inside right
front of stove as shown in Figure 13.

3.

Slip left side of rod down into slot on inside left front of stove
(see Figure 13).

Figure 12 - Assembling Rod and Screen

Slot on Inside Left
Front of Stove

Rod

Figure 13 - Installing Screen Into Stove (View From Back of
Stove)

Rings

Hole on Inside Right
Front of Stove

Rod with Screen
Assembled

Advertising