VEHICLE TUBING INSTALLATION

1. Mount all components in a suitable location, preferably in a high area above the air system.

Do not mount in engine compartment or near any source of heat or dirt . The system may

be connected to any point in the vehicle's air system .

2. Mount air compressor in a vertical position as shown.

3.

CAUTION no condensate or water must be allowed to enter or accumulate in the output of

the Auto Pump . Route output pressure line downward from Auto Pump to permit moisture

to drain away .

Water in the pump outlet will induce failure .

DRAIN CONDENSATE SEPARATOR WEEKLY

4. All connections for air lines are 1/4" NPT . Use Teflon tape, or equivalent on all

connections to insure no leakage of air.

5. The recommended installation of the Auto Pump air compressor system is shown below.

6. Note that an external check valve is located between the compressor and the pressure

switch. No additional check valve is required.

7. Mount the air compressor. Connect a suitable piece of flexible tubing from the outlet port of

compressor to the air tank . (Tubing and connectors are not supplied.)

8. An optional Mounting Plate 091-9H-1 is available to reduce any vibration and noise from the

Auto Pump and to simplify pump mounting.

Auto Pump

Air Pressure System

Air Line

The Flow of

Any Moisture

1/4" NPT

Outlet Port

Truck

Body

Optional

Mounting

Plate kit

091-9H-1

Note: compressor must be mounted above

air tank to assure that moisture will flow

away from the compressor