Installation wiring diagram, 8 amp fuse, 171-ind auxiliary battery main battery – Kussmaul Electronics 091-171 User Manual
Page 5
Advertising

Chassis
Ground
Chassis
Ground
Chassis
Ground
FUSE
INPUT
OUTPUT
L N
+ +
REMOTE
BAT 1
BAT 2
4
9
5
6
7
8
2
3
1
10
+12VOLT
FROM
STARTER
+12VOLT
FROM
IGNITION
SWITCH
THIS LINE SUPPLIES
THE POWER TO OPERATE
THE SYSTEM
THIS LINE ENERGIZES THE
SOLENOID AT ENGINE START
IF THE AUXILIARY BATTERY
HAS SUFFICIENT VOLTAGE
TO PROVIDE A BOOST
#2
A
W
G
M
IN
.
Line
Neutral
Ground
115 VAC,
AWG 16
MINIMUM
#
12
A
W
G
W
IR
E
M
IN
.
#
12
A
W
G
W
IR
E
M
IN
.
#1
2
A
W
G
W
IR
E M
IN
.
#16 AWG WIRE MIN.
#16 AWG WIRE MIN.
8 AMP FUSE
0
25
091-171-IND
AUXILIARY
BATTERY
MAIN
BATTERY
INSTALLATION WIRING DIAGRAM
FIGURE 2
IMPORTANT:
NOTE: Wire size is for a maximum length of 20 feet. If wiring is to be longer, larger
wiring is required. Additional information is available on request.