1

LINE INPUT
Balanced line input XLR / 6,3mm jack (combo).

2

SUB LEVEL
Subwoofer volume.

3

SUB PHASE
Inverts the phase of the subwoofer (0° / 180°) if necessary.

4

SUB FREQ
Adjusts the upper cut-off frequency of the subwoofer (80 - 200 Hz Low-Pass).

5

LINE DIRECT OUTPUT
Balanced XLR line output.

6

POWER LED

7

SIGNAL LED
Lights up when the unit receives an audio signal.

8

LIMIT LED
Lights up when the limiter is active. The limiter function protects your subwoofer from damage. If the limiter
LED lights up permanently, reduce volume.

9

POWER
Switches power on/off.

10

MAINS SOCKET (VOLEX POWER PLUG)
with built-in fuse holder. AC connection via IEC connector (220 - 240V AC). A power cord with a lockable
Volex connector is supplied with this unit. IMPORTANT: Replace fuse only by fuse of same type and rating! If
fuse blows repeatedly please contact authorized service center!