Is-0327 rev. d – Legrand AU1002 User Manual

Page 4

Advertising
background image

INSTRUCTION / INSTALLATION SHEET
lyriQ™ Four Source, Eight Zone
Audio Distribution Module

IS-0327 Rev. D

301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com

©Copyright 2008 by On-Q/Legrand All Rights Reserved.

Page 4 of 4

B. "TRIM-OUT" STEPS

1. At the location of the lyriQ™ Single Source Input, if it is a Flush-mount version (P/N AU1004), terminate one of

the Cat 5e cables with an RJ-45 Plug using the T568A wiring standard, then plug it into the back of the Flush-
mount Single Source Input and mount it in the low voltage bracket or electrical box. If it is a standalone version
(P/N F7398), pull the Cat 5e cable from the enclosure through the low voltage bracket or electrical box, and
terminate it on an RJ-45 insert, then snap it into a wall plate which is mounted to the low voltage bracket or
electrical box.

2. At the location of the Triple Source Input, if it is a Flush-mount version, terminate two of the Cat 5e cables with

RJ-45 Plugs using the T568A wiring standard, then plug them into the back of the Flush-mount Triple Source
Input and mount it in the low voltage bracket or electrical box and cover with a wall plate. If it is a standalone
version (P/N F7428), pull two Cat 5e cables from the enclosure through the low voltage bracket or electrical box,
and terminate them on RJ-45 inserts, then snap them into a wall plate which is mounted to the low voltage
bracket or electrical box. Then run Cat 5e jumpers from wall plate to the Triple Source Input.

NOTE: The lyriQ™ Four Source, Eight Zone Audio Distribution Module has three source input jacks labeled
“Single” and “Multi A and B”. It is very important that the Cat 5es from the Source Inputs are run from the
correct source to the correct jack. Make sure that no Power Supplies are connected to the Audio Distribution
Module before performing the next steps.

3. At the enclosure: Install the lyriQ™ Four Source, Eight Zone Audio Distribution Module in an On-Q style

enclosure using the included plate's tabs and push pins. If installing into an existing Greyfox style bracket, simply
discard the mounting plate and secure the module to the bracket with the push pins in each module corner.

4. Terminate the three Cat 5e cables run from the single and triple sources with RJ-45 plugs using the T568A wiring

standard.

5. Plug the Cat 5e cable from the Single Source Input into the SOURCES -> SINGLE jack on the 4x8 module.

6. Plug the Cat 5e cable from the “A” output of the Triple Source Input into SOURCES -> MULTI A jack on the

distribution module.

7. Plug the Cat 5e cable from the “B” output of the Triple Source Input into SOURCES -> MULTI B jack on the

distribution module.

8. At the enclosure: Terminate each Cat 5e cables coming from each room with a volume control using the T568A

wiring standard, then plug each of those cables into the Zone Output jacks on the distribution module.

9. If using High Performance Keypads, connect the 16/4 speaker wires from each room with a High Performance

volume control to the High Performance Power Distribution Module (see Figure 4).

10. If applicable, expand the system by connecting one or more lyriQ™ Single Source, Four Zone Distribution

Modules to the Zone Out jacks on the Four Source, Eight Zone Audio Distribution Module.

11. Plug the appropriate number of 24 volt power supply cables into the Power jacks on the 4x8 Module (depending

on Zone and High Performance Keypad usage).

12. Verify system functionality.

Advertising