Defrost timer, Defrost timer programming guide (all models), Programming example – Delfield Glass Door Merchandisers 6000 User Manual

Page 7: Typical sequence of operation, Cycle time

Advertising
background image

Vantage 6000™ Series and Glass Door Merchandisers Reach-Ins Service and Installation Manual

For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com

6

Vantage 6000™ Series and Glass Door Merchandisers Reach-Ins Service and Installation Manual

7

For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com

Programming Example


Defrost

Cycle

Time

Time

1 2 3 4

1 2 3 4

40 Minute Duration

6 Hour Frequency

Typical Sequence of Operation

Period

Frost Build Time

40 Min

Compressor

Defrost terminated by

Defrost

time or temperature

6 Hour Cycle

Next cycle begins

Defrost Timer Programming Guide (all models)

A (2) 4 position dip switch provides user con-
trol of defrost duration and cycle time. The
selection is as follows.

Defrost Time

Dip Switch
Setting

min

off

off

off

off

void

on

off

off

off

5

off

on

off

off

10

on

on

off

off

15

on

on

off

on

20

on

off

on

off

25

off

on

on

off

30

on

on

on

off

35

off

off

off

on

40

on

off

off

on

45

off

on

off

on

50

on

on

off

on

55

off

off

on

on

60

Cycle Time

Dip Switch
Setting

hrs

off

off

off

off

void

on

off

off

off

2

off

on

off

off

4

on

on

off

off

6

on

on

off

on

8

on

off

on

off

10

off

on

on

off

12

on

on

on

off

14

off

off

off

on

16

on

off

off

on

18

off

on

off

on

20

on

on

off

on

22

off

off

on

on

24

O

N

O

N

Defrost timer

NOTE: Dip switches shown in default positions.

PURPLE

WHITE

COMPRESSOR
LINE N/O

BR
O

WN

BLA

CK

BLA

CK

YELLO

W

DEFROST
LINE N/O

N

P1

CYCLE
TIME

DEFROST
TIME

DEFROST
INITIATE

DEFROST ON
INITATE

X

P2

CR

P3

1

2

3

4

O N

PB

LED

1

2

3

4

O N

Advertising