Venting installation instructions – Desa VC42NE SERIES User Manual

Page 12

Advertising
background image

www.desatech.com

116237-01E

12

VENTING INSTALLATION

INSTRUCTIONS

Continued

Figure 13 - Typical Horizontal

Termination Cap Mounting with

Additional Siding Standoff Installed

Siding Standoff

Screws

High Wind
Termination

Apply
Mastic to
Outside
Edge of
Standoff

Exterior Wall with Vinyl Siding

10

3

/

4

" x 10

3

/

4

"

Framed Opening

Maintain 1"
Minimum Air
Space Around
Outer Pipe When
Penetrating a Wall

Minimum Pipe
Overlap 1

1

/

4

"

Wall
Firestop

Direct-Vent
Pipe

Horizontal Termination Configurations

Figures 14 through 18 show different configura-

tions and alternatives for venting with horizontal

termination. Each figure includes a chart with

critical minimum and maximum dimensions which

MUST be met. IMPORTANT: Remember that a

horizontal run of venting must have a 1/4" rise for

every 12" of run toward the termination.

NOTICE: Do not seal termination

cap to vent pipe. Cap must be

removable for vent inspection

and maintenance.

WARNING: Never run vent

downward as this may cause

excessive temperatures which

could cause a fire. Operation of

improperly installed and main-

tained venting system could

result in serious injury, property

damage or loss of life.

GROUND FLOOR INSTALLATION

Recommended Applications:

• Installation using cabinet surrounds

• Through the wall using round or square termina-

tion

(up to 12" horizontal pipe)

• NOT FOR CORNER INSTALLATION

Horizontal
High Wind
Square
Termination

Wall Firestop

45° Elbow

Figure 14 - Horizontal Termination

Configuration for Square or Round

Terminations

45° Elbow

Wall
Firestop

Horizontal
Round
Termination

Exterior Portion of
Wall Firestop (Round
Termination Only)

Adjustable
Pipe 12" Max.

Round Termination

Square Termination

Vertical (V)

Horizontal (H)

32

3

/

4

" min.

17" max.

* If installing this fireplace at altitudes of
4000 feet and above, it is recommended
that an additional vertical height of 6" be
added to the vent system.