Installation and operating instructions, Connection diagram – Louroe Electronics LE-072 User Manual

Page 3

Advertising
background image

CONNECTION DIAGRAM

Verifact C Microphone

TO LOUROE BASE

STATION OR AUDIO

AUDIO INTERFACE

ADAPTER

RED

wire (12 Vdc) connects to Terminal A

BLACK wire (Audio) connects to Terminal B

wire (Ground) connects to Terminal C

BARE

If using recommended wiring (West Penn 452)

MICROPHONE SENSITIVITY SWITCH

The microphone pre-amp (PC board) contains a sensitivity switch with two positions:

N represents normal sensitivity (zero dB @ 1,000)

L represents lower sensitivity (-6 dB @ 1,000)

Microphone is always shipped in the N position. For less microphone sensitivity,
move slide switch to L position. Do not change unless required.

INSTALLATION TIPS

1. Use overall shielded audio cable only. West Penn 452, Belden 8451 or equivalent.

UNSHIELDED CABLE IS NOT SATISFACTORY FOR SOUND SYSTEMS.

2. When used at a cash register checkout, microphone should be installed closer to the customer rather than the cash

register, as the drawer sound could dominate the recording. It should be installed closest to the

area to be monitored and documented.

3. Avoid installing microphone near air vents, air conditioners, fans and other equipment that generate

high sound and air pressure.

4. If microphone is installed in a police interview room, room should be conditioned with any type of carpeting, acoustical

ceiling tiles, acoustical foam, etc. to reduce echo. This will enhance the quality of live and recorded audio.

5. The APR-1 and microphone should have a barrier or solid wall between them in order to avoid audio

feedback, especially when they are in close proximity to each other. If no barrier, microphone should be at least 25’

from APR-1 to avoid acoustical feedback.

2 Conductor shielded cable, 22
gauge with a 24 gauge drain wire

NOTE:

Unshielded cable is not

satisfactory for audio systems

WIRING REQUIREMENTS

West Penn 452 or equivalent

A (12 Vdc)
B (Audio)
C (Ground)

A

L

C

B

N

Page 3 of 4

LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406

TEL (818) 994-6498

FAX

994-6458

website: www.louroe.com e-mail: [email protected]