If using cable from other manufacturers, color code may vary.

Verifact D and D-V microphones are designed to be installed in a single gang electrical box for flush or surface
mounting to a wall or ceiling. It should be positioned 3 to 6 ft. from the area of desired coverage. Ceiling heights in
excess of 10 ft. should be avoided.

MECHANICAL INSTALLATION:

Verifact D and D-V Microphones connect directly to any Louroe Audio Base Station or to a Louroe Audio Interface
(Model IF-1, IF-2, IF-4 and IF-8). A small terminal block is located on the microphone pre-amp, and marked A, B,
C.
Using recommended cable, connect as follows:

Red wire connects to terminal A (+12Vdc)
Black wire connects to terminal B (audio output)
Bare wire connects to terminal C (ground)

MICROPHONE CONNECTION:

CONNECTING VERIFACT D OR D-V MICROPHONE TO A LOUROE BASE STATION OR
AUDIO INTERFACE ADAPTER (IF-1, IF-4 or IF-8)
All Louroe base stations and audio interface adapters have a corresponding terminal block
marked A, B C for each audio zone. Bring in other end of cable from the microphone and connect
to the terminal block (or blocks) matching

A to A
B to B
C to C

Maximum cable run between microphone and base station/interface adapter is 1,000 ft.

MODEL D OR D-V MICROPHONE

2 CONDUCTOR SHIELDED

22 GAUGE, with a 24 gauge drain wire

WEST PENN

452 OR EQUIVALENT

C

B

A

BLACK

BLACK

BARE

BARE

RED

RED

TO LOUROE

BASE STATION

OR

AUDIO

INTERFACE

ADAPTER

A

B

C

2 Conductor shielded cable,
22 gauge with a 24 gauge
drain wire

WIRING REQUIREMENTS

INSTALLATION AND OPERATING INSTRUCTIONS

Page 2 of 4