Speedaire, Portable air compressor – Speedaire 5Z598C User Manual

Page 6

Advertising
background image

6

Speedaire Operating Instructions and Parts Manual

5Z598C

Excessive tank pressure – safety valve
pops off

Air leaks at fittings

Air leaks at check valve

Air leaks at pressure switch release valve

Air leaks from air tank

1. Move the pressure switch lever to the

OFF position. If the outfit doesn'tshut
off, and the electrical contacts are
welded together, replace the pressure
switch If the contacts are good, check
to see if the pin in the bottom of the
pressure release valve is stuck. If it does
not move freely, replace the valve

2. Return the outfit to a Service Center to

check and adjust, or replace switch

Tighten fittings where air can be heard
escaping. Check fittings with soapy
water solution. DO NOT OVER-TIGHTEN

Defective check valve results in a constant
air leak at the pressure release valve when
there is pressure in the tank and the
compressor is shut off. Remove and clean
or replace check valve. DO NOT OVER-
TIGHTEN

1. Remove and replace the release valve

2. A defective CHECK valve results in a

constant air leak at the pressure release
valve when there is pressure in the tank
and the compressor is shutoff. Remove
and clean or replace check valve. DO
NOT OVER-TIGHTEN

Air tank must be replaced. Do not repair
the leak

DO NOT DRILL INTO,
WELD, OR OTHERWISE

MODIFY AIR TANK OR IT WILL WEAKEN

Performing repairs may expose voltage sources, moving parts, or compressed air sources.
Personal injury may occur. Prior to attempting any repairs unplug the power cord and bleed off

air pressure.

Corrective Action

Symptom

Troubleshooting Chart

1. Pressure switch does not shut off motor

when compressor reaches "cut-out"
pressure

2. Pressure switch "cut-out" too high

Fittings are not tight enough

Defective or dirty check valve

1. Defective pressure switch valve

2. Defective check valve

Defective air tank

Possible Causes

Clean or replace regulator

If there is an excessive amount of pressure
drop when the accessory is used, adjust the
regulator
NOTE: Adjust the regulated pressure under
flow conditions (while accessory is being
used)

Dirty or damaged regulator internal parts

It is normal for "some" pressure drop to
occur

Regulator knob – continuous air leak
Regulator will not shut-off air outlet

Pressure reading on the regulated
pressure gauge drops when an accessory
is used

Speedaire

Portable Air Compressor

®

E

N
G

L

I

S

H

Advertising