Symptom

Cause / Solution

Page

Power turns off and the power

indicator flashes red approx. every 0.5

seconds.

• Due to the temperature rise within this unit, the protection circuit is working. Turn off the

power and wait about an hour until this unit sufficiently cools down. Then, turn on the power

again.

• Please re-install this unit in a place having good ventilation.

39

Power turns off and the power

indicator flashes red approx. every

0.25 seconds.

• Check the speaker connection. The protection circuit may have been activated because

speaker cable core wires came in contact with each other or a core wire was disconnected

from the connector and came in contact with the rear panel of this unit. After unplugging the

power cord, take corrective action such as firmly re-twisting the core wire or taking care of the

connector, and then reconnect the wire.

• Turn down the volume and turn on the power again.

16, 39

25, 26

When the power is turned on, the

power indicator flashes red approx.

every 0.25 seconds.

• This unit’s amplifier circuit has failed. Turn off the power and please contact the Marantz

service adviser.