Operating heater, Continued, Lighting instructions – Desa 6000 BTU/HR User Manual

Page 10

Advertising
background image

10

103112

VENT FREE PROPANE/LP GAS HEATER

BLUE FLAME 6000 BTU/HR

Shutting Off Heater

1.

Turn control knob clockwise

Clockwise

to the PILOT position.

2.

Press in control knob and turn clock-
wise

Clockwise

to the OFF position.

Shutting Off Burner Only (pilot
stays lit)

1.

Turn control knob clockwise

Clockwise

to the PILOT position.

1.

Remove front panel (see Figure 10,
page 7).

2.

Follow steps 1 through 5 under Light-
ing Instructions
.

3.

With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.

4.

Keep control knob pressed in for 30
seconds after pilot is lit. After 30 sec-
onds, release control knob.

5.

Replace front panel.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation at the top of page 16. If you
don’t smell gas, go to the next step.

5.

Press in control knob and turn coun-
terclockwise

C-clockwise

to the PILOT

position. Keep control knob pressed
in for five (5) seconds (see Figure 16,
page 16).

Note:

You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop up

when released, contact a qualified
service person or gas supplier for
repairs.

6.

With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the front of burner. The pilot can
be seen through the glass panel. If
needed, keep pressing ignitor button
until pilot lights.

OPERATING
HEATER

Continued

Thermocouple

Pilot
Burner

Ignitor
Electrode

Figure 17 - Pilot

CAUTION: Do not try to adjust

heating levels by using the
manual shutoff valve.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop up

when released, contact a qualified
service person or gas supplier for
repairs.

Note:

If pilot goes out, repeat steps

3 through 7.

8.

Turn control knob counterclockwise

C-clockwise

to the HIGH position. The

main burner should light. Set control
knob to any heat level between HIGH
and LOW. To turn control knob from
HIGH to a lower setting, press in the
control knob and turn counterclock-
wise

C-clockwise

.

Note:

Both HIGH and LOW are

locked positions. You must press in
control knob before turning it from
these positions.

LIGHTING
INSTRUCTIONS

OFF

HIGH

PILOT

LOW

IGNITOR

Ignitor Button

Control Knob

Figure 16 - Control Knob In The OFF
Position

1.

STOP! Read the safety information,
page 9, column 3.

2.

Make sure manual shutoff valve is
fully open.

3.

Turn control knob clockwise

Clockwise

to the OFF position.

Note:

If pilot does not stay lit, refer

to Troubleshooting, pages 12 through
14. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot
with match. To light pilot with match,
see Manual Lighting Procedure
.

TO TURN OFF GAS
TO APPLIANCE

MANUAL LIGHTING
PROCEDURE

Advertising