TROUBLESHOOTING GUIDE

PROBLEMS

CAUSES

SOLUTION


ON POSITION 6 (MAXIMUM)
THE FLAME IS LONG AND
SMOKY, THERE IS SUIT
BUILD UPON THE GLASS.


Position 6 was reached too
quickly.


1. Set flow regulating handle

to position 1;

2. wait for combustion to

stabilize;

3. Progressively

increase

flow

to desired position.

NOTE

: SEE LIGHTING

PROCEDURES.

Maximum flow is too high.

1. Set flow to a lower position;
2. Call a qualified technician

to adjust the valve.

ON POSITION 1 (MINIMUM)
THE FLAME PRODUCES
SMOKE AND SUITS THE
GLASS.

Cleaning tee and/or burner are
dirty.

1.

Activate cleaning tee
according to procedures;

2. Schedule at the next shut

off to clean the burner.

Orifice of plunger is partially
plugged.

1. Progressively

increase

flow

to position ‘’6’’;

2. Push in many consecutive

times on the thermostatic
regulator bottom to remove
dirt form the orifice.

NOTE : If the problem persist,
you may have to remove and
clean out the valve with alcohol.
Call your specialized
technician.

ON POSITION 1 (MINIMUM)
THE FLAME PRODUCES
SMOKE AND SUITS THE
GLASS.

Flow is to low.

1. Slightly increase the flow

regulating handle;

2.

Call a specialized
technician.

Page 11 of 15