9 $aa4 – Measurement Computing CB-7011 User Manual

Page 30

Advertising
background image

30

CB-7011/CB-7011D, CD-7018 User’s Manual

2.9 $AA4

Description: Read Synchronized Data

Note: The command is for CB-7011/11D/11P/11PD only.

Syntax: $AA4[CHK](cr)

$

delimiter character

AA

address of reading module (00 to FF)

4

command for reading synchronized data

Response:

Valid Command:

>AAS(Data)[CHK](cr)

Invalid Command:

?AA[CHK](cr)

Syntax error or communication error may get no re-

sponse.

!

delimiter for valid command

?

delimiter for invalid command or the module does not

receive command #** before the command $AA4.

AA

address of response module(00 to FF)

S

status of synchronized data, 1 = first time read, 0 =

has been read

(Data)

synchronized data, format reference Sec. 1.10

Example:

See example of Sec. 2.2 #**

Related Command:

Sec. 2.2 #**

Advertising